A service person was performing routine battery maintenance using an aerosol battery terminal protector on a haul truck’s batteries. While spraying the aerosol the spray can contacted the positively charged busbar and the battery box lid strut, immediately causing a short circuit.
MAG – Safety Alert – Aerosol Battery Terminal Protector and Fire